Replacement radiator size check: pipe centres, wall distance and valves
This page is for you if you're swapping an existing radiator and want the new one to fit the pipes you already have. Answer four questions, read off the table and you'll know the maximum body width, which panel type suits your wall distance, and whether you need extension tails or corner valves. We cover measuring and fitting, not gas work or heat loss calculations.
As an Amazon Associate we earn from qualifying purchases. This does not change your price.
Will a new radiator fit my existing pipes? 4 checks
- Where do your pipes come from: up through the floor, or out of the wall below the radiator?Look at the pipe below each valve. Pipes rising from the floor usually take angled or straight valves. Pipes coming straight out of the wall under the radiator connection usually need corner valves. Write down which one you have on each side.
- What are your pipe centres in mm?Measure from the centre of the left pipe to the centre of the right pipe, at floor level rather than up at the valve, because old valves can lean. If finding the centre is fiddly, measure outside edge to outside edge and subtract one pipe diameter: 15 mm for standard copper, 8 or 10 mm for microbore
- How far is each pipe centre from the finished wall?Measure from the wall surface (not the skirting) to the middle of each pipe where it meets the valve. Do both sides, as they are not always equal. Or measure the gap between the back of the pipe and the wall, then add half the pipe diameter (7.5 mm for 15 mm pipe).
- Are you keeping the old valves or fitting new ones?Valves plus tails take up room on each side of the radiator body. Many suppliers work with about 40 mm per side, but it varies with the valve. If you're buying new valves, check the valve drawing on the product page or in the PDF for the figure from the tail thread to the valve centre. If you're kee
Quick reference
| Your measurement | What it means | What to buy or do |
|---|---|---|
| Pipe centres minus 2 x valve allowance gives a standard width (e.g. 1080 mm minu | Like-for-like width is possible | Radiator with that body width and the same panel type. Check the wall-to-pipe fi |
| Calculated body width falls between standard sizes | New radiator will be narrower than the gap | Pick the next standard width down. Close the gap per side with solid extension t |
| Gap per side of roughly 5 to 100 mm | Within the range of common extension tails | Solid chrome tails, 1/2 in BSP, cut to length or combined. Fit one per side so t |
| Gap per side well over 100 mm (typical with old imperial radiators) | Metric sizes are a poor match | Look at imperial-sized ranges such as Myson Premier HE Imperial, or plan pipewor |
| The new radiator would need wider pipe centres than you have | Tails can't shorten anything | Choose a narrower radiator or have the pipework moved |
| Wall to pipe centre around 48 to 50 mm | Typical for a Type 11 (single convector) on its short bracket leg | Type 11. Check the maker's drawing for the short and long leg figures |
| Wall to pipe centre around 55 to 65 mm | Typical for a Type 21 (P+); some Type 11 on the long leg | Type 21, or Type 11 on the long leg. Check the drawing |
| Wall to pipe centre around 70 mm or more | Typical for a Type 22 (K2, double convector) | Type 22. Check the drawing for the exact figure |
| Wall to pipe centre below about 40 mm (old flat panel without fins) | Most modern panels sit further out | Look for brackets with a shallow setting, or plan small pipework changes |
| Left and right wall distances differ, or differ from the new radiator by more th | The pipe will be under strain | Small differences can be taken up if the valve sits well above the floor. Larger |
| Pipes come out of the wall under the radiator | Angled valves won't line up | Corner valves, sometimes combined with a short tail |
Our picks
Solid chrome radiator extension tails, 1/2 in BSP
They screw into the radiator inlet and move the valve connection outwards to meet your pipes. Solid tails come in fixed lengths and can be cut down or combined to make up the gap.
View on AmazonAdTelescopic (adjustable) radiator valve extension
The length adjusts within a range, so you don't need to cut it. On trade forums they have a reputation for leaking, so treat them as a second choice behind solid tails.
View on AmazonAdAngled TRV and lockshield set, 15 mm (e.g. Drayton TRV4)
A new valve pair has a known allowance per side, so the sums are reliable. Check the valve drawing before you choose the radiator width.
View on AmazonAdCorner radiator valve pair, 15 mm
Corner valves turn the wall pipe up into a side tapping, which angled valves can't do neatly.
View on AmazonAdMyson Premier HE Imperial panel radiator
The range comes in inch-based widths, e.g. 53 in (1352 mm) and 69 in (1759 mm), so you can often get close to the old pipe centres. Imperial and metric heights differ, so check the height too.
View on AmazonAdType 11 / Type 22 compact convector radiator (metric)
Standard body widths like 900, 1000, 1200 and 1400 mm are easy to find. Choose the type that matches your wall-to-pipe distance, not just the width.
View on AmazonAdThread sealing cord or PTFE tape for radiator tails
Every extra threaded joint needs sealing. DIYers on UK forums mention sealing cord such as Loctite 55 when refitting tails.
View on AmazonAdCommon buying mistakes
- Ordering by radiator width alone. Measure the pipe centres, subtract the valve allowance for both sides, and only then pick a width.
- Measuring from pipe edges or from the top of a leaning valve. Measure centre to centre at floor level, or take outside to outside minus one pipe diameter.
- Assuming 40 mm per side for every valve. Check the drawing for your exact valve, especially traditional or old valves.
- Upgrading from Type 11 to Type 22 for more heat at the same width without checking the wall-to-pipe distance. The tappings sit further from the wall and the pipes may not reach.
- Forgetting that most brackets have two settings. Try both the short and long leg figures before deciding the pipework has to change.
- Buying a radiator that is wider than the pipes allow. Extension tails only make up a gap; they can't make the centres narrower.
Why isn't radiator width the same as pipe centres?
The width on a product page is the radiator body. With side tappings, the valves and tails sit outside the body on each side, so the pipe centres are always wider than the radiator. Two radiators with the same width can still have different pipe centres. With bottom-entry models, such as many towel rails, the maker gives the centres directly and you don't add anything for the valves.
How much should I allow for the valves on each side?
Many UK suppliers work with about 40 mm per side. For example, a 1000 mm body with 40 mm valves gives 1080 mm pipe centres. That isn't a standard figure though. Traditional, decorative and some angled valves add a slightly different amount, and older valves are often bulkier than modern ones. Use the figure from the drawing of the exact valve you're fitting. If you keep your old valves, measure their allowance on the current radiator.
What does the wall-to-pipe centre measurement tell me?
It shows how far from the wall the radiator tappings need to sit. It depends on the panel type and on the bracket: most brackets give a short and a long setting. In one maker's fitting chart, the short and long settings were 48/68 mm for Type 11, 56/76 mm for Type 21 and 73/93 mm for Type 22. Other makes differ by a few mm, so check the drawing. Moving from a Type 11 to a Type 22 usually brings the tappings further out than your pipes.
Can I fit a narrower radiator and close the gap with extension tails?
Yes, if the new radiator is narrower than the space between your pipes. Work out the gap per side and fit a tail on each side so the radiator stays centred. Solid tails come in lengths up to around 100 mm and can be cut to size. If the new radiator needs wider centres than you have, tails won't help and the pipework has to move.
What if my old radiator is in imperial sizes?
Older UK radiators were often made in inch sizes, so a metric replacement can leave an awkward gap. One option is an imperial-sized range, such as Myson Premier HE Imperial. The other is the nearest metric width with longer tails. Remember that metric and imperial heights also differ.
Will a smaller or different radiator still heat the room?
Heat output depends on height, width and panel type. In Myson's Premier HE data, a 300 x 1200 mm Type 22 is listed at 1201 W, a Type 21 at 942 W and a Type 11 at 618 W. If you go narrower or change type to suit the pipes, compare the watt or BTU figure with the old radiator. If you're unsure about the heat loss, get a heating engineer to check it.
FAQ
What are radiator pipe centres?
The distance from the centre of the left pipe to the centre of the right pipe, in mm. It's the figure that decides whether a new radiator connects without pipework changes.
My pipe centres are 1080 mm. What width radiator do I need?
With valves that need 40 mm per side, it's a 1000 mm body. If your valves need more or less, adjust the figure: pipe centres minus twice the valve allowance.
Is there a UK standard for pipe centres?
No. Valves and pipe sizes are standardised, but pipe centres depend on the radiator make and how it was installed. Always measure your own.
Can I replace a radiator without moving the pipes?
Often, yes. You need the same or a slightly narrower width (with tails to make up the difference) and the same wall-to-pipe distance within a few mm.
How much difference in wall distance can the pipes take?
Only a few mm. More is possible if the valves sit well above the floor, because a longer pipe flexes more easily. Beyond that, the pipework needs changing.
Do I have to drain the system to fit extension tails?
Not always. Some DIYers isolate the radiator at both valves just to add tails. Replacing the valves themselves usually means draining down. If you're unsure, ask a plumber.
Does this page replace a heating engineer?
No. It helps you measure and pick the right parts. Heat loss, system pressure, inhibitor and anything to do with the boiler or gas are jobs for a qualified engineer.
Do you earn money from the links?
Yes. If you buy through our links, we may earn a commission. It doesn't change the price you pay or what we recommend.
More guides
- Radiator pipe centres size guide UK: how to measure and match
- How to Measure Radiator Pipe Centres
- Radiator wall distance: how to measure it and what to do with the number
- Radiator valve spacing check for UK replacements
- Double panel radiator sizes UK: Type 21 and Type 22 height, width and depth
- Standard radiator sizes in the UK: heights, widths and panel types
- 600mm high radiators in the UK: widths, panel types and what fits your wall
- 700mm high radiators in the UK: widths, clearances and fit
- 400mm high radiators in the UK: which width and type fits
Sources
- Checkatrade: How to Measure a Radiator (Width, Height & Pipe Centres)
- HomeServe: How to measure a radiator
- Geyser: How to Measure for a New Radiator: Pipe Centres, Wall Space and Valve Allowance
- Geyser: Choosing the Right Designer Radiator Valves
- The Radiator Company: What Are Pipe Centres and How Are They Measured?
- The Radiator Company: A Quick Guide to Replacing a Radiator Like-for-Like
- Trade Radiators: Shop for Radiators by Pipe Centre
- Trade Radiators: How to Use Radiator Valve Tail Extensions